Tool Wear Monitoring in the Grinding Process Based on Acoustic Emission Count Deviation

Authors

  • João Alisson Gonçalves Alves

Keywords:

Acoustic Emission, Sensors, Dressing, Grinding, Tool Condition Monitoring, Signal Processing, Acoustic Emission Counts

Abstract

Tool Condition Monitoring in the grinding process is fundamental to ensuring a high surface finish and precise dimensional tolerances, with the use of Acoustic Emission (AE) sensors standing out in this task. However, correlating raw data with the physical wear of the tool remains a challenge that often requires complex modeling. To fill this gap, this study proposes the analysis of a new analytical metric for monitoring the wear of single-point dressers: the Count Deviation, which measures the relative growth of acoustic activity compared to a reference signature extracted from a new tool. The acoustic emission signals were evaluated and filtered in the 34-42 kHz band, selected with the aid of the Correlation Coefficient Deviation Metric (CCDM). The results demonstrated that the Count Deviation satisfactorily reflects the progression of wear over the number of passes.

Downloads

Published

2026-10-05